| Foundation: | Column foundation |
| Super Structure: | RCC framed structure and 9" thick external panel walls and 41/2 thick partition walls with brick masonry and plastering. |
| Doors: | Entrance Doors:Teakwood frame, teakwood shutters with view panel and surface finished with melamine mat polish.
Hardware:Stainless steel hardware fittings. |
Other doors:Teakwood frame, membrane paneled shutters with paint finish. Hardware:Stainless steel hardware fittings. |
|
| Windows: | Padoc wood windows with glazed shutters with paint finish security M.S Grills. |
| Flooring: | Branded vitrifield tiles of ISI make with suitable shade. Skirting: 3" height granite. |
| Bathroom: | Floor:Antiskid ceramic tiles. Walls:Glazed tiles up to 7' height. Counter:White marble counter with circular wash basin of suitable color. CP Fixtures:Towel rod, Hot & Cold water mixer, ablution tap etc., |
| Kitchen: | Counter:Black Granite Sink:Stainless Steel Sink (Double bowl single drain) of standard make. Wall:Wall dado tiles up to 3' height above the kitchen counter. CP Fixtures:Drinking water & bore well water tap. |
| Staircase: | Tread & Riser: Good quality granite slab. Skirting:Granite 3" height. Handrails:Teakwood balusters and top railing(melamine mat polish). |
| Painting: | Internal Walls: Two Coats of POP putty and one coat cement primer and 2 coats of emulsion paint of suitable color. External Walls:One coat of white cement and two coats grade emulsion paint. Others:Door shutters, grill, gate etc., painted with two coats of enamel paint over one coat of primer. |
| Plumbing: | Internal plumbing line concealed and external open. UPVC piping for cold water and CPVC piping for hot water line. |
| Sanitary Fixtures: | ISI approved standard make of suitable color. |
| Electrical: | Three phase supply through individual DB and ELCB Common Generator backup of capacity 1500 Watts or 1.5 KVA Invertor / Domestic, UPS - (Nominal maintenance charge for common genset applicable) Wiring Good quality standard IS specified make (Finolex) Switches:Good quality IS specified modular types(Make: MDS, Legrand or MK) |
| Roof & Terrace: | Flat Roof:Surki and burnt clay weathering tiles. Stopped Roof:Mangalore pattern tiles. |
Compound Wall: | Wall:5' height with 4 1/2" brick wall or Hallow Block construction. Gate:14" wide MS gate. Driveway:Designer paver tiles. |